satellite tracking program, like Orbitron sends the MD-01 an elevation
angle less than 20 degree for an azimuth angle in 10 to 100 degree
range the MD-01 will only take the elevation angle to 20 degree.
The Elevation map is ignored when the MD-01 is controlling manually.
Note: ANGEL MIN and MAX ANGLE in SET MOTOR 1 (SET MOTOR 2) have a higher
priority than the angles of elevation map. The rotator will not go
beyond these limits.
Const EL MAP
If this option is set to ON, option USE EL. MAP is ignored. And a
minimum elevation angle of 0 degrees azimuth is set for all Azimuth
angles.
This option is ignored when MD-01 is controlling manually.
Note: ANGEL MIN and MAX ANGLE in SET MOTOR 1 (SET MOTOR 2) have a higher
priority than the angles of elevation map. The rotator will not go
beyond these limits.
Start
Motors run mode:
This is set for each motor separately in modules SET MOTOR 1 and SET
MOTOR 2, as described later,
IMMEDIATELY - motor starts with max speed, Soft start not active.
SOFTLY – so-called soft start
Stop
Motors stop mode:
This is set for each motor separately in modules SET MOTOR 1 and SET
MOTOR 2, as described later,
IMMEDIATELY – at once, Soft stop not active.
SOFTLY – so-called soft stop