Example 2: three-step
Set the POWER START 1 = 20%
START POWER 2 = 30%,
START POWER 3 = 50%,
START TIME 1 = 3 seconds,
START TIME 2 = 3 seconds,
START TIME 3 = 3 seconds,
MAX POWER = 100%.
This means that the rotator starts with 20% power, within 3
seconds power reaches 30%, followed by 3 seconds power reaches
50% and last 3 seconds power up to 100%.